CMC Series

COOL YOUR WATER FLOWS IN DIFFERENT SIZES

This range of cooling tower cells is designed to cool small water flows. There are 7 different sizes that cover water flows from 5 to 150 m3 per hour. The towers are completely prefabricated and shop tested. The thermal performance of these cooling towers is optimized with regard to the use of water and power consumption. Noise production of the standard tower is low due to the configuration with an axial ventilator. In case of severe noise requirements several extensions are possible. The equipment is full corrosion resistant and provides a long lasting reliable solution for generation of cold water.

Selecting a cooling tower
The water temperatures (hot water in and cold water out), the wet bulb temperature of the site of installation, the required water flow and the noise level are the 4 major factors in order to select a wet cooling tower. After analyzing your needs, we will propose the most appropriate technical and economic solution.There are Polacel CMC standard solutions for every need starting from a water flow to cool of 90 m3/h. Our engineers can also make special adaptations of the standard cooling towers in order to meet the most specific of your needs.The various type of available heat exchange surfaces allows us to select a suitable fill whether of the “film” type or of the “splash” type . The heat exchange fill is chosen according to the quality of water to be cooled (clean or highly polluted water), but also depending on the specific environment of the site and considering to the process to be cooled. In all cases, a chemical treatment of the cooling water is required. This shall be implemented by a specialized company based on the maximum concentration values ​​advocated by Kelvion.

Polacel CMC = thermal performance certified by CTI STD-201
The thermal performance of  Polacel CMC cooling towers from Kelvion B.V. are certified according to the CTI STD-201 standard (Cooling Technology Institute). This certification is the assurance for our customers to have a cooling tower that cools the water at the required temperature. It eliminates costly in-situ performance tests. The Polacel CMC cooling towers are equipped with axial fans driven by geared motors. The geared motors being usually controlled by variable speed drives, the Polacel CMC cooling towers thus contribute to the reduction of operational costs (OPEX) of the tower and therefore of your entire installation.

ADVANTAGES

  • This design has been proven for many years permit to reduce the maintenance to a minimum but also to obtain a high efficiency
  • easy access to all the internal component of the cooling tower
  • Kelvion has the ability to deliver and assemble these cooling towers in a very short time
  • Thanks to their optimized size, Polacel CMC cooling towers are delivered in two pre-assembled modules
  • Polacel CMC cooling towers are recognized for their high reliability and for the quality

REQUEST INFORMATION





I have read and agree to the Privacy Policy


Show Buttons
Hide Buttons
PGlmcmFtZSBzcmM9Imh0dHBzOi8vZWZwcy5nci93cC1jb250ZW50L3VwbG9hZHMvaG90c3BvdC1maWxlcy9oeWdoc3Bpbi9pbmRleC5odG0iICB3aWR0aD0iMTAwJSIgaGVpZ2h0PSIxMDAlIj48L2lmcmFtZT4=
PGlmcmFtZSBzcmM9Imh0dHBzOi8vZWZwcy5nci93cC1jb250ZW50L3VwbG9hZHMvaG90c3BvdC1maWxlcy9oeWdoc3Bpbi1leHRlbmRlZC9pbmRleC5odG0iICB3aWR0aD0iMTAwJSIgaGVpZ2h0PSIxMDAlIj48L2lmcmFtZT4=
PGlmcmFtZSBzcmM9Imh0dHBzOi8vZWZwcy5nci93cC1jb250ZW50L3VwbG9hZHMvaG90c3BvdC1maWxlcy9oeWdoc3Bpbi1ob3BwZXIvaW5kZXguaHRtIiAgd2lkdGg9IjEwMCUiIGhlaWdodD0iMTAwJSI+PC9pZnJhbWU+
PGlmcmFtZSBzcmM9Imh0dHBzOi8vZWZwcy5nci93cC1jb250ZW50L3VwbG9hZHMvaG90c3BvdC1maWxlcy9oeWdoc3Bpbi1kb3VibGUtZmxvdy9pbmRleC5odG0iICB3aWR0aD0iMTAwJSIgaGVpZ2h0PSIxMDAlIj48L2lmcmFtZT4=


Dear partners,

We would like to inform you that in the framework of preventive measures aimed at effectively addressing the spread of “Covid19” disease and in accordance with the National Public Health Organization guidelines (https://eody.gov.gr/), our company is committed to ensure public health, safety of its partners and employees. Therefore we have recommended the fulfillment of our employees' tasks through teleworking.

The duration of this measure is initially set from 17.03.2020 to 30.04.2020

The design provides full operation, but due to special conditions, delays in specific tasks or communication may occur.

Our company will strive to keep its operation uninterrupted and secure by serving its clientele in ways and timeframes that are judged possible.

We thank you for understanding and we remain at your disposal.


Αγαπητοί Συνεργάτες,

Θα θέλαμε να σας ενημερώσουμε ότι στο πλαίσιο μέτρων πρόληψης με σκοπό την αποτελεσματική αντιμετώπιση εξάπλωσης του κορωνοιού και σύμφωνα με τις οδηγίες υγιεινής & ασφάλειας που έχει ορίσει ο ΕΟΔΥ (https://eody.gov.gr/), η εταιρία μας για να διασφαλίσει τη δημόσια υγεία, την ασφάλεια των συνεργατών και των εργαζομένων της, συστήσαμε την εκπλήρωση των καθηκόντων των εργαζομένων μας, μέσω τηλεργασίας.

Η διάρκεια του συγκεκριμένου μέτρου ορίζεται αρχικά από τις 17.03.2020 έως τις 30.04.2020

Ο σχεδιασμός προβλέπει πλήρη λειτουργία, ωστόσο εξαιτίας των ειδικών συνθηκών, ενδέχεται να παρουσιαστούν καθυστερήσεις σε συγκεκριμένες εργασίες ή και στην επικοινωνία.

Η εταιρία μας θα προσπαθήσει να διατηρήσει αδιάληπτη και ασφαλή την λειτουργία της, εξυπηρετώντας το πελατολόγιο της με τρόπους και σε χρονικά πλαίσια που κρίνονται δυνατά.

Σας ευχαριστούμε για την κατανόηση και παραμένουμε στην διάθεση σας.