Goedhart FC38L

SLIM LINE COMMERCIAL AIR COOLER (COPPER/ALUMINIUM)

Goedhart FC38L is range of “slim line” standard air coolers for cold storage rooms with height limitation.

Kelvion Goedhart Commercial Air Cooler FC38L
Kelvion Goedhart Commercial Air Cooler FC38L

The commercial range Goedhart FC38L ceiling mounted air coolers are standard air coolers for cold storage rooms with height limitation. Goedhart FC38L is a standard product to ensure shorter delivery times. The circuiting of these evaporators has been optimized according to the most commonly used refrigerants/coolants and conditions. Because of this each Goedhart FC38L air cooler has his own order code, easy for purchasing. The air direction is blow-through as Standard.

ADVANTAGES

  • Long-term assurance: highly efficient, ErP 2015 fans
  • Dual discharge air throw: blow-through
  • Easy removable cover plates
  • Delivered in a wooden crate
  • Low height: The maximum space in the chill room can be utilised
  • Circuiting is optimized according to the most commonly used refrigerants/coolants and conditions. Easy to order by an order code each air cooler
Application For cold storage rooms with hiright limitation
Engineering Level Level 1, Commercial products
Number of types 54
Capacities HFO/HFK 1,1 – 20 kW (R404A dx – SC2)
Capacities Coolant 1,9 – 34 kW (E-glycol 28% tl1=12°C tin=-2°C tout=3°C)
Fan sizes 250, 300, 350 and 400 mm
Max. number of fans each aircooler 4
Air configuration vertical air-on, horizontal blow-through
Suitable for almost all known refrigerants and coolants, with the exception of NH3
Tube pitch staggered
Fin spacing 4 and 7 mm
Tube material Copper 12 mm i = internally enhanced tubes for refrigerants p =internally plain tubes for coolants(G) and refrigerants(DX)
Fin material Goedhart aluminum ht-fins
  • Construction for ceiling mounting
  • Casing material of galvanized sheet steel
  • The drip tray is hinged and made from light Aluminium
  • Executed with a short air conduction plate as standard
  • Standard white epoxy spray finishing
  • Bend/header protection by end covers, easy removed formaintenance
  • Standard refrigerant connections are positioned on te left hand side of the unit when looking with the direction of the airflow
  • Possible defrost by hot gas spiral or electric defrost elements will be fixed to the bottom side of the coil
  • Stainless steel fasteners
Show Buttons
Hide Buttons
PGlmcmFtZSBzcmM9Imh0dHBzOi8vZWZwcy5nci93cC1jb250ZW50L3VwbG9hZHMvaG90c3BvdC1maWxlcy9oeWdoc3Bpbi9pbmRleC5odG0iICB3aWR0aD0iMTAwJSIgaGVpZ2h0PSIxMDAlIj48L2lmcmFtZT4=
PGlmcmFtZSBzcmM9Imh0dHBzOi8vZWZwcy5nci93cC1jb250ZW50L3VwbG9hZHMvaG90c3BvdC1maWxlcy9oeWdoc3Bpbi1leHRlbmRlZC9pbmRleC5odG0iICB3aWR0aD0iMTAwJSIgaGVpZ2h0PSIxMDAlIj48L2lmcmFtZT4=
PGlmcmFtZSBzcmM9Imh0dHBzOi8vZWZwcy5nci93cC1jb250ZW50L3VwbG9hZHMvaG90c3BvdC1maWxlcy9oeWdoc3Bpbi1ob3BwZXIvaW5kZXguaHRtIiAgd2lkdGg9IjEwMCUiIGhlaWdodD0iMTAwJSI+PC9pZnJhbWU+
PGlmcmFtZSBzcmM9Imh0dHBzOi8vZWZwcy5nci93cC1jb250ZW50L3VwbG9hZHMvaG90c3BvdC1maWxlcy9oeWdoc3Bpbi1kb3VibGUtZmxvdy9pbmRleC5odG0iICB3aWR0aD0iMTAwJSIgaGVpZ2h0PSIxMDAlIj48L2lmcmFtZT4=